PKDZ 770/11/5,08-V GN
Product information:
Three-level PCB terminal, Screw connection, No. of poles: 11, Width: 58.42 mm, Colour: Green
Product number:
12933.1
GTIN (EAN):
4044211039899
Quantity:
General | |
---|---|
Packaging unit: | 50 |
Quantity unit: | PC |
Packaging type: | Carton |
Type of banding: | Without |
Weight per piece (not including packaging): | 88 g |
Weight per piece (including packaging): | 89.9 g |
Unit of weight: | G |
Customs number: | 85369010 |
Country of origin: | QU |
Colour: | Green |
Dimensions | |
---|---|
Length: | 33.3 mm |
Length of the pin: | 5 mm |
Width: | 58.42 mm |
Width left: | 5.08 mm |
Width right: | 2.54 mm |
Height: | 44.8 mm |
Drill hole diameter: | 1.3 mm |
Diameter of connecting pin: | 0.9 mm |
Pitch: | 5.08 mm |
Ratings | |
Rated voltage: | 250 V |
Rated current: | 22 A |
Rated cross-section: | 2.5 mm² |
Rated impulse voltage: | 2 kV |
Overvoltage category: | III |
Contamination degree: | 3 |
Connection data | |
Connection principle: | Screw connection |
Connection type of PCB: | Solder connection |
Type of attachment to circuit board: | Connecting contact |
Angle of PCB/wire connection: | 0°/180° (horizontal) |
Number of electrical connections: | 33 |
No. of poles: | 11 |
Number of levels: | 3 |
Wire cross-section single-core (rigid) / stranded, min.: | 0.2 mm² |
Wire cross-section single core (rigid)/stranded, max.: | 4 mm² |
Wire cross-section stranded, min.: | 0.2 mm² |
Wire cross-section stranded, max.: | 2.5 mm² |
Wire cross-section stranded with wire-end ferrules, min.: | 0.25 mm² |
Wire cross-section stranded with wire-end ferrules, max.: | 2.5 mm² |
Wire cross-section AWG, min.: | 30 |
Wire cross-section AWG, max.: | 12 |
Stripping length: | 8 mm |
Screw threading: | M 3 |
Torque: | 0.5 Nm |
Materials | |
Insulation housing: | Polyamide 6.6 |
Flammability class UL 94: | V-0 |
Working temperature, min.: | -30 °C |
Working temperature, max.: | 105 °C |
Clamping element: | Brass |
Screws: | Steel |
Soldering lug: | Copper alloy |
Further technical data | |
Storage temperature, min.: | -40 °C |
Storage temperature, max.: | 105 °C |
Insulation resistance: | 1*10^13 Ohm x cm |
Creepage-current resistance: | CTI 600 |
Glow wire flammability index GWFI: | GWFI 850 |
GWFI after-glow time: | 30 Sek. |
Glow wire ignition temperature GWIT: | GWIT 775 °C |
GWIT exposure time: | 5 Sek. |
Connection cycles, in compliance with standard: | 5 |
Recommended wave soldering temperature: | 265 °C |
Recommended wave soldering duration, min.: | 3 Sek. |
Recommended wave soldering duration, max.: | 4 Sek. |
Environmental Product Compliance | |
REACH Conform: | No |
REACH Reference date: | 2024-06-27 |
REACH Candidate Substance Note: | No |
REACH CAS 1 Substance: | LEAD |
REACH CAS 1 Percent minimal: | 0.1 % |
REACH CAS 1 Percent maximum: | 4 % |
REACH CAS 1 Number: | 7439-92-1 |
RoHS Conform: | Yes |
RoHS Exception rule: | 6c |
cUL Recognized | |
---|---|
cUL approval: | CSA 22.2 No.158 |
cUL Usegroup B: rated voltage: | 300 V |
cUL Usegroup B: rated current: | 20 A |
cUL Usegroup C: rated voltage: | 150 V |
cUL Usegroup C: rated current: | 20 A |
cUL Usegroup D: rated voltage: | 300 V |
cUL Usegroup D: rated current: | 10 A |
cUL wire cross-section single-core (rigid) AWG, min.: | 30 |
cUL wire cross-section single-core (rigid) AWG, max.: | 12 |
cUL wire cross-section stranded AWG, min.: | 30 |
cUL wire cross-section stranded AWG, max.: | 12 |
cUL torque: | 0.4499999881 Nm |
cUL wire material: | Cu |
cUL Recognized: | |
UL Recognized | |
UL approval: | UL 1059 |
UL Usegroup B: rated voltage: | 300 V |
UL Usegroup B: rated current: | 20 A |
UL Usegroup C: rated voltage: | 150 V |
UL Usegroup C: rated current: | 20 A |
UL Usegroup D: rated voltage: | 300 V |
UL Usegroup D: rated current: | 10 A |
UL wire cross-section single-core (rigid) AWG, min.: | 30 |
UL wire cross-section single-core (rigid) AWG, max.: | 12 |
UL wire cross-section stranded AWG, min.: | 30 |
UL wire cross-section stranded AWG, max.: | 12 |
UL torque: | 4 Lb In |
UL wire material: | Cu |
UL factory wiring: | |
UL field wiring: | |
UL Recognized: | |
VDE approval | |
VDE approval: | DIN EN 60998 |
VDE approval granted: | |
VDE rated voltage: | 250 V |
VDE rated current: | 22 A |
VDE rated current wire cross-section rigid, max.: | 22 A |
VDE rated current wire cross-section stranded, max.: | 22 A |
VDE rated impulse voltage: | 2 kV |
VDE wire cross-section rigid, min.: | 0.5 mm² |
VDE wire cross-section rigid, max.: | 2.5 mm² |
VDE wire cross-section stranded, min.: | 0.5 mm² |
VDE wire cross-section stranded, max.: | 2.5 mm² |
VDE screw threading: | M 3 |
VDE torque: | 0.5 Nm |
VDE overvoltage category: | III |
VDE contamination degree: | 3 |