FSIK 4/2A/LED 110-250V AC/DC BK
Product information:
Fuse-disconnect terminal, Push-in connection, Mounting type: Mounting rail TS 35/7.5, Rated cross-section: 4 mm², Width: 6 mm, Colour: Black
Product number:
3293.4
GTIN (EAN):
4044211188986
Quantity:
General | |
---|---|
Packaging unit: | 25 |
Quantity unit: | PC |
Weight per piece (not including packaging): | 87.56 g |
Weight per piece (including packaging): | 87.66 g |
Unit of weight: | G |
Customs number: | 85369010 |
Country of origin: | DE |
Product description: | Fuse-disconnect terminal |
Colour: | Black |
Dimensions | |
---|---|
Length: | 67.5 mm |
Width: | 6.1 mm |
Height: | 69 mm |
Height TS 35/7.5: | 70 mm |
Ratings | |
Rated voltage (determined by the illuminated display and fuse being used): | 250 V |
Rated current: | 6.3 A |
Rated cross-section: | 4 mm² |
Rated impulse voltage: | 6 kV |
Overvoltage category: | III |
Contamination degree: | 3 |
Maximum power dissipation for nominal condition: | 0.2 W |
Connection data | |
Connection principle: | Push-in connection |
Connection position: | Top |
Connections: | 2 / extraction lever |
Number of terminals per level: | 2 |
Number of levels: | 1 |
Wire cross-section single-core (rigid) / stranded, min.: | 0.2 mm² |
Wire cross-section single core (rigid)/stranded, max.: | 4 mm² |
Wire cross-section stranded, min.: | 0.2 mm² |
Wire cross-section stranded, max.: | 2.5 mm² |
Wire cross-section stranded with wire-end ferrules, min.: | 0.2 mm² |
Wire cross-section stranded with wire-end ferrules, max.: | 2.5 mm² |
Wire cross-section AWG, min.: | 24 |
Wire cross-section AWG, max.: | 10 |
Stripping length: | 12 mm |
Materials | |
Insulation housing: | Polyamide 6.6 |
Flammability class UL 94: | V-0 |
Working temperature, min.: | -40 °C |
Working temperature, max.: | 120 °C |
Further technical data | |
Mounting type: | Mounting rail TS 35/7,5 |
Fuse size: | 5 x 20 mm |
Gauge plug acc. to EN 60 947-1: | A3 |
Number of cross-connection channels: | 1 |
End plate required: | |
Voltage fuse: | 250 V |
Voltage illuminated display: | 110-250 V |
Cross-current via illuminated display: | 5 mA |
Power loss in singular arrangement - overload and short-circuit protection, max.: | 4 /6,3 W / A |
Power loss in compound arrangement - overload and short-circuit protection, max.: | 1,6 / 6,3 W / A |
Power loss in singular arrangement - only short-circuit protection, max.: | 4 / 10 W / A |
Power loss in compound arrangement - only short-circuit protection, max.: | 4 / 6,3 W / A |
Version of fuse holder: | Swivelling |
Type of display element (defect display): | LED |
Version of fuse cartridge: | G fuse 5 x 20 |
Supply voltage (defect display), min.: | 110 |
Supply voltage (defect display), max.: | 250 |
Type of voltage (defect display): | AC/DC |
Environmental Product Compliance | |
REACH Conform: | yes |
REACH Reference date: | 2024-01-23 |
REACH Candidate Substance Note: | No |
RoHS Conform: | yes |
CSA approval | |
---|---|
CSA approval: | C22.2 No 158 |
CSA approval granted: | |
CSA Usegroup C: rated voltage: | 300 V |
CSA Usegroup C: rated current: | 6,3 A |
CSA wire cross-section AWG, min.: | 24 |
CSA wire cross-section AWG, max.: | 10 |
CSA stripping length: | 12 mm |
CSAus approval | |
CSAus approval: | UL 1059 |
CSAus approval granted: | |
CSAus Usegroup C: rated voltage: | 300 V |
CSAus Usegroup C: rated current: | 6,3 A |
CSAus wire cross-section AWG, min.: | 24 |
CSAus wire cross-section AWG, max.: | 10 |
CSAus stripping length: | 12 mm |
KEMA KEUR approval | |
KEMA KEUR approval: | EN 60947-7-3:2009 |
KEMA KEUR approval granted: | |
KEMA rated voltage: | 250 V |
KEMA voltage fuse, max.: | 250 V |
KEMA rated current: | 6,3 A |
KEMA rated impulse voltage (fuse holder without electrical components): | 6 (4) kV |
KEMA wire cross-section single core (rigid), min.: | 0.2 mm² |
KEMA wire cross-section single-core (rigid), max.: | 4 mm² |
KEMA wire cross-section stranded, min.: | 0.2 mm² |
KEMA wire cross-section stranded, max.: | 4 mm² |
KEMA fuse size: | 5 x 20 mm |
KEMA power loss in singular arrangement - overload and short-circuit protection, max.: | 4 /6,3 W / A |
KEMA power loss in compound arrangement - overload and short-circuit protection, max.: | 1,6 / 6,3 W / A |
KEMA power loss in singular arrangement - only short-circuit protection, max.: | 4 / 10 W / A |
KEMA power loss in compound arrangement - only short-circuit protection, max.: | 4 / 6,3 W / A |
UL Recognized | |
UL approval: | UL 1059 |
UL Usegroup B: rated voltage: | 300 V |
UL Usegroup B: rated current: | 6,3 A |
UL Usegroup C: rated voltage: | 300 V |
UL Usegroup C: rated current: | 6,3 A |
UL Usegroup D: rated voltage: | 300 V |
UL Usegroup D: rated current: | 6,3 A |
UL wire cross-section single-core (rigid) AWG, min.: | 24 |
UL wire cross-section single-core (rigid) AWG, max.: | 10 |
UL wire cross-section stranded AWG, min.: | 24 |
UL wire cross-section stranded AWG, max.: | 10 |
UL wire material: | Cu |
UL factory wiring: | |
UL field wiring: | |
UL Recognized: |
File | Language | Type | Size | Version |
---|---|---|---|---|
CAD_3293_FSIK_4_2A_LED_110-250V_AC_DC | STP | 2.87 MB | 9/29/18 |
- End plate
- Wire-end ferrule for compact connection spaces
- End stop
- Insulated cross-connector
- Quick marking
- Screwdriver
- Connecting sleeve